Whole-House Generator Fuel Calculator (Propane and Natural Gas)

See how long your standby generator will run on a propane tank, whether the tank will last a long outage, and what each day costs on propane or natural gas. Fuel use comes from the manufacturer's published figures. Change anything and the answer updates instantly; nothing is sent to a server.

Fuel runtime calculator

Generator

About 50% is typical when the AC cycles on and off.

Propane tank

Tanks are filled to 80% at most, so 80% is full.

Outage

Runtime on propane

About 4.9 days

22 kW on a 500-gal propane tank at 50% load

A 7-day outage

Needs about 426 gallons ($1,998). Your tank has 300 usable gallons between 80% and 20%.

Plan on 1 refill: you'd be about 126 gallons short.

  • Propane deliveries can take days after a hurricane. Top off the tank before the storm and schedule refills early.
At 50% load on propane
Fuel per hour2.53 gal
Cost per hour$11.89
Cost per day (24 h)$285.38
By load (500-gal tank)
LoadPer hourPer dayOn your tank
25%1.85 gal$208.126.8 days
50%2.53 gal$285.384.9 days
75%3.22 gal$362.653.9 days
100%3.90 gal$439.923.2 days
By tank size (50% load, 80% to 20%)
TankUsableRuntime
120 gal72 gal28.4 hours
250 gal150 gal2.5 days
500 gal300 gal4.9 days
1,000 gal600 gal9.9 days

How this calculator works

Generator makers publish fuel use at half load and full load. The calculator draws a straight line through those two points to estimate fuel use at your load, from 25% to 100%. For propane, it divides the usable fuel in your tank by that rate. Usable fuel is the gallons between the gauge reading when the outage starts and the level where you'd call for a refill. Costs use your fuel price.

Load is the hard part to guess. A generator rarely runs at full load for long: the AC cycles on and off, and the big appliances only run part of the time. About 50% is a reasonable planning number for a home whose generator was sized with a safety margin. If you came from the size calculator, the "Use my loads" button shows the worst case: everything you picked running nonstop.

Fuel use by generator size

From Generac's published figures: Guardian series for air-cooled sizes, RG Protector for 32 kW and up. Your model's spec sheet or fuel decal is the final word.

SizePropane, half loadPropane, full loadNatural gas, halfNatural gas, full
10 kW 0.97 gal/h 1.48 gal/h 101 ft³/h 127 ft³/h
14 kW 1.81 gal/h 3.07 gal/h 195 ft³/h 256 ft³/h
18 kW 1.70 gal/h 3.02 gal/h 169 ft³/h 247 ft³/h
22 kW 2.53 gal/h 3.90 gal/h 204 ft³/h 327 ft³/h
24 kW 2.53 gal/h 3.90 gal/h 203 ft³/h 306 ft³/h
26 kW 2.06 gal/h 3.63 gal/h 188 ft³/h 333 ft³/h
32 kW 2.70 gal/h 4.60 gal/h 226 ft³/h 375 ft³/h
38 kW 2.90 gal/h 5.20 gal/h 255 ft³/h 437 ft³/h
48 kW 4.20 gal/h 6.60 gal/h 336 ft³/h 607 ft³/h

A bigger generator doesn't always burn more. Newer engine designs can be more efficient, which is why the 18 kW and 26 kW use less at half load than the 14 kW and 22 kW.

How long a propane tank lasts

At half load, running from a full tank (80%) down to 20%:

Tank18 kW22 kW26 kW
120 gal 42.3 hours28.4 hours34.9 hours
250 gal 3.7 days2.5 days3 days
500 gal 7.4 days4.9 days6.1 days
1,000 gal 14.7 days9.9 days12.1 days

After a hurricane, propane trucks can take days to reach you. Fill the tank before storm season, top it off when a storm is forecast, and plan the refill level with that delay in mind.

Natural gas: no tank, but not free

A natural-gas generator has no tank to run out; it runs as long as the utility keeps gas flowing. It still costs money every hour. A 22 kW generator at half load uses about 204 cubic feet an hour, about $124.85 a day at $2.55 per 100 cubic feet, the 2025 Florida residential average. Your utility's rate may be higher or lower.

Ways to make fuel last longer

Worked examples

Frequently asked questions

How long will a 500-gallon propane tank run a whole-house generator?
A 22 kW generator at half load burns about 2.53 gallons an hour. A full 500-gallon tank holds about 400 gallons (tanks are filled to 80%). Running from full down to 20%, that's about 4.9 days; running it nearly empty stretches it to about 6.6 days.
How much does it cost to run a whole-house generator per day?
For a 22 kW generator at half load, about $285.38 a day on propane at $4.70 a gallon, or about $124.85 a day on natural gas at $2.55 per 100 cubic feet. Lighter loads cost less.
Can a natural gas generator run out of fuel?
Not the way a propane tank does. It runs as long as the gas utility keeps pressure in the line, which it usually does during a power outage. Damage to gas lines, such as from flooding, can interrupt it.
Why is a propane tank only filled to 80%?
Propane expands as it warms, so tanks are filled to about 80% to leave room. That's why a 500-gallon tank holds about 400 gallons of fuel.
Does a standby generator burn fuel when the power is on?
A little. It runs a short self-test on a schedule to keep the engine ready. That's small next to an outage, but it slowly lowers a propane tank between fills.

Last reviewed November 26, 2026.